| Sign In | Join Free | My wpc-board.com |
|
Maintenance : Minimal, designed for CIP and SIP processes
Application : Production of ultrapure water for pharmaceutical, biotech, and food industries
Product name : Hot Water Sanitizable EDI Module
Electrical consumption : Low (specific value depends on model)
Module dimensions : Varies by model (e.g., 600 x 300 x 150 mm)
Conductivity range : 0.1 to 1.0 µS/cm
Installation type : Inline or skid-mounted
Operating temperature range : 5 °C to 45 °C
Maximum sanitization temperature : 85 °C
Operating pressure : 1 to 6 bar
Recovery rate : Typically 90-95%
Place of Origin : China
Model Number : EIMD-10HP
Sanitization method : Hot Water
Flow rate : Varies by model (e.g., 1-10 m³/h)
Technology : Electrodeionization (EDI)
Brand Name : Aquacells
Certification : FDA,EU,CE,RoHS ,REACH
Material compatibility : Sanitary-grade materials compatible with hot water
The Aquacells EIMD-HP module is specifically engineered for hot water sanitization applications and is widely utilized in Pharmaceutical, biotechnology, and cosmetics industries. Constructed from high-temperature resistant materials to accommodate instantaneous heating and cooling requirements, this module delivers a constant flowrate of high-purity water without the need for chemical regeneration.
| Parameter | Specification |
|---|---|
| FCE (including CO2 and Silica) | < 45 µS/cm |
| Temperature | 5-45 ℃ (40-113 ℉) |
| Feed pressure | 1.4-7 bar (20-100 psi) |
| Total Chlorine (as CI2) | <0.05ppm |
| Fe | <0.01ppm |
| Mn | <0.01ppm |
| S2- | <0.01ppm |
| pH | 4-11 |
| Total Hardness (as CaCO3) | <1.0 ppm |
| Dissolved Organics (TOC as C) | <0.5 ppm |
| Silica (SiO2) | <1.0 ppm |
| Parameter | Performance |
|---|---|
| Typical Recovery | 90-95% |
| Maximum Feed Pressure | 7 bar (100 psi) |
| Maximum Feed Temperature | 45 ℃ (113 ℉) |
| Sanitization Temperature at 30 psi (2.0 bar) | 85 ℃ (185 ℉) |
| DC Voltage* | 0-600 V |
| DC Amperage | 0-10 A |
| Product Conductivity | <0.1 µS/cm |
| Silica (SiO2) Removal | 90-99% depending on feed water |
The information provided in this brochure contains general descriptions or performance characteristics that may not always apply as described in actual use cases or may change due to further product development. An obligation to provide the respective characteristics shall only exist if expressly agreed upon in the terms of the contract.
|
|
Hot Water Sanitizable Electrodeionization EDI Module For Pharmaceutical Biotech Industries Images |